Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise

Brand Name : LABNOVATION

Model Number : LD-560

Certification : IFCC, NGSP, CE

Place of Origin : Shenzhen, China

MOQ : 1 Unit

Price : USD7,000.00-12,000.00/Unit

Supply Ability : 100 Units/Day

Delivery Time : 15-20 working days

Packaging Details : Carton Size: 480mm×480mm×615mm, Gross Weight: 28kgs

Principle : HPLC (High Performance Liquid Chromatography)

Test Speed : 90s/test

Sample types : Whole blood or Pre-diluent sample

Test blood volume : 5μL in whole blood mode; 150μL in pre-diluted mode

Sample loading method : Continuous automatic sample loading

Sample capacity : 20 samples

Reagent pack : 600T

Column test quantity : 3000T

Eluent Kind : Eluent A, Eluent B

Data storage : 5000

Built-in Thermal Printer : Yes

CV : <2%

Test range : 3.0%~18.0%

Operation screen : 10" Full color LCD display

Gross Weiht : 28kg

Dimensions : 378(L) ×380(W)×510(H)mm

Shelf Life : 5 years

Contact Now

Fully Automated Glycosylated Hemoglobin HbA1c Analyzer HPLC System


Intended use


The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.The Fully automatedHbA1c Analyzer LD-560 offers the fast throughput of HbAlc results in 90 seconds, with Hb variant detection, providing the outstanding solution for quick and reliable diabeticmonitoring. No sample preparation and very little hands-on time by the operator is required for the LD-560 Analyzer.
HPLC Methodology
High-Pressureliquid Chromatography (HPLC), to separate HbAlc directly with measuring the absor bance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbAla,HbAlb,HbF,HbAlc,LAlc,HbAO peak areas and ratio. And the result also includes IFCC, NGSP and ADAG value for diverse client n eeds.
Performance

*HPLC Technology-Gold Standard Methodology

Anchored to the Diabetes Control and Complication Trial (DCCT) reference study NGSP and IFCC certified

*Fast -To Ensure Your Workload is Processed Promptly

HbAlc results in 90 seconds
*Fully Automated-To Minimize Operation Hassles

Automated Piercing
Fully Automated Start-up, Maintenance and Shutdown Internal Auto Barcode Scanner for Sample identification
*Precise and Reliable -To Serve You Consistently

HbAlc Inter & Intra Measuring CV<2% to Enable Exceptional Result Management Superior Quality Chromatographic Resolution to Minimize Interferences

Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise

  • 10-30 daily samples
  • 90 seconds / Test
  • 10” LCD touch screen
  • 28 kgs only

Specification


Instrument Manufacturer Lanovation
Manufacture location Shenzhen, China
Model LD-560
Dection information Principle method HPLC
Detection method Dual wavelengh colorimetry
Wavelength 420nm
Test Speed 90 Seconds/test
Test Speed throughtput 40 Samples per hour
Sample information Sample types Whole blood or Pre-diluent sample
Sample volume 5μL in whole blood mode
150μL in pre-diluted mode
Sample capacity 20 samples
Sample loading method Continuous automatic sample loading
Mixer No, but probe mixing samples
Reagent and other consumble Column test quantity 3000T
Reagent pack 600T(Reagent)/ 3000T(Column) separate
Eluent 2
Operation and character information Operation screen 10 inch Full color LCD display
Data storage 5000
Built-in Thermal Printer Yes
Performance information CV <2%
Test range 3.0%~18.0%
 
Package Information
Dimensions 378(L) ×380(W)×510(H)mm
Weight 28kg

Product Composition

Main Parts

The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.



Reagents and Consumables

The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
Eluent A/Eluent B/Eluent C(Variant Mode) Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
Hemolysis Reagent Used to dissolve red blood cells and release hemoglobin.
Chromatography Column Used for separation and elution of glycosylated hemoglobin and non glycated.
Hemoglobin Filter Used to initially filter the sample after hemolysis.
Paper Rolls Prints a report of the test results.
Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise

Certificate


Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise


Product Tags:

Fast HbA1c HPLC analyzer

      

Automated HPLC Glycated Hemoglobin Analyzer

      

HPLC HbA1c Glycated Hemoglobin Analyzer

      
China Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise wholesale

Fully Automated HbA1c Glycated Hemoglobin Analyzer HPLC System Fast Precise Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)