Sign In | Join Free | My frbiz.com
China Labnovation Technologies, Inc. logo
Labnovation Technologies, Inc.
Labnovation Technologies,Inc.
Active Member

4 Years

Home > POCT HbA1c Analyzer >

Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection

Labnovation Technologies, Inc.
Contact Now

Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection

Brand Name : LABNOVATION

Model Number : LD-100

Certification : IFCC, NGSP, CE

Place of Origin : Shenzhen, China

MOQ : 1

Price : Negotiation

Payment Terms : D/A, D/P, T/T

Supply Ability : 100/Day

Delivery Time : 15-20 working days

Packaging Details : Carton

Name : Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion

Sample Type : Whole blood

Test Time : ≤2 Minutes

Sample Volume : 4μL

Test Range : 4%-15%

Shelf life of test kit : 9 Months

Contact Now

Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion

Smart Auto Hematology HbA1c Analyzer POCT Glycosylated Hemoglobin Detechtion is intended for measuring glycoslated hemoglobin (HbA1c) in human blood.

According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021.

With the development of modern medicine, people pay more and more attention to their own health and the diagnosis and control of diabetes has become a hot topic. As we know, diabetes is a group of metabolic diseases characterized by hyperglycemia. Every Patient with diabetes is adviced to have their HbA1c tested for 2-4 times annually.


Specification

Model LD-100
Method Boronate Affinity
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Shelf life of test kit 9 months
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm


Principle

The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.

Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection

The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.

After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence

After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.

After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.

Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.


Feature

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).



Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-15% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.

Certificate

Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin DetectionSmart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection


Product Tags:

Smart Auto POCT HbA1c Analyzer

      

Hematology POCT HbA1c Analyzer

      
China Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection wholesale

Smart Auto Hematology POCT HbA1c Analyzer Glycosylated Hemoglobin Detection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)